HostCompliance.uk

Holiday let EICR and electrical safety: what each nation says

Of the rules in force that this site read, only Scotland sets an electrical inspection interval for short-term lets in its own rules. Wales has passed one that is not in force yet. gov.uk tells holiday let owners in England to follow the rented-sector guidance, but the regulations behind it cover tenants whose let is their only or main home.

At a glance

  1. Scotland: a licence needs an electrical inspection by a competent person at least every five years, an EICR on fixed installations and a PAT report on moveable appliances guests can use.
  2. England: gov.uk tells holiday let owners to follow HSE electrical guidance and the rented-sector guidance. The rented-sector regulations cover tenants who occupy as their only or main residence.
  3. Wales: the electrical condition report rule sits in the Renting Homes rules. A holiday tenancy or licence is not an occupation contract unless the landlord gives notice that it is.
  4. PAT: HSE's guidance for workplaces says the law does not require annual portable appliance testing. Equipment must be maintained to prevent danger.
  5. Northern Ireland: not checked yet.

Official pages read 22 November 2026. Each is listed at the end of this page.

England: what gov.uk says for holiday lets

The gov.uk page for self-catering holiday homes has an electrical safety section. It says you must follow the HSE guidance on electrical safety and the guidance on electrical safety standards in the private and social rented sectors. Letting out a self-catering holiday home in England (opens in a new tab). Last updated 2 October 2026.

That rented-sector guidance explains the Electrical Safety Standards in the Private Rented Sector and Social Rented Sector (England) Regulations 2020. The table shows what those regulations and the guidance cover.

PointWhat the regulations and guidance say
Who is coveredA tenancy that gives the right to occupy as an only or main residence and provides for rent. Regulation 2 (opens in a new tab). The guidance says a tenancy includes a licence to occupy.
InspectionThe installation must be inspected and tested by a qualified person at least every 5 years.
The reportA copy goes to existing tenants within 28 days of the inspection, and to a new tenant before they occupy.
Excluded lettingsSchedule 1 lists, among others, shared accommodation with the landlord or the landlord's family, long leases, student halls, hostels and refuges, care homes, hospitals, and moveable structures, vehicles and vessels. Schedule 1 (opens in a new tab).
Holiday letsRegulation 2, Schedule 1 and the guidance do not mention holiday lets.

Source for the inspection and report rows: Electrical safety standards in the private and social rented sectors: guidance (opens in a new tab).

So gov.uk tells holiday let owners to follow guidance that includes a five-year inspection, while the regulations that guidance explains cover main-home tenancies. This site has not found an official page that settles how the five-year rule applies to holiday guests. It does not say the rule cannot apply. Whether a let falls inside the regulations depends on its facts.

The HSE electrical safety pages that gov.uk links to are written around hazards at work. HSE: electrical safety (opens in a new tab). The pages read do not mention landlords, holiday lets or guests.

Portable appliances and PAT testing

HSE answers common questions about portable appliance testing. Its points:

Source: HSE PAT questions (opens in a new tab).

HSE's leaflet INDG236 covers low-risk settings such as offices, shops and some parts of hotels. It suggests visual inspections at first intervals of between six months and four years, depending on the equipment. It suggests a portable appliance test at first intervals of between one and five years for equipment that is not double insulated. It says labels and records can help but are not a legal requirement. HSE INDG236 (opens in a new tab). The intervals are in the INDG236 leaflet (PDF) (opens in a new tab).

Both HSE pages are written for employers and workplaces. Neither names holiday lets. Scotland is different: its licence conditions require a PAT report and labels, as set out below.

Scotland: the licence electrical conditions

Scottish Government guidance for hosts lists these conditions where the premises has electrical fittings or items:

  1. Keep electrical fittings and items in a reasonable state of repair and in proper and safe working order.
  2. Arrange an electrical safety inspection by a competent person at least every five years, or more often if that person directs.
  3. Make sure the competent person produces an Electrical Installation Condition Report on any fixed installations.
  4. Have a competent person produce a Portable Appliance Testing report on moveable appliances a guest has access to.
  5. Have each inspected moveable appliance date labelled and signed.

The guidance points to Scottish Government statutory guidance on electrical installations and appliances in private rented property. It says Annex A of that guidance sets out who is competent to produce an EICR. It says the standards for private residential tenancies also apply to short-term lets. Scottish Government guidance, section 2 (opens in a new tab).

mygov.scot lists the EICR and the PAT report among the documents you must have. Guests must be able to access a copy of both, along with fire, gas and electrical safety information. Legal requirements for short-term let accommodation (opens in a new tab). Last updated 9 October 2025.

Neither page read states how often PAT must be repeated. This site has not read the statutory guidance itself. The Scotland licensing page covers the rest of the licence.

Wales: occupation contracts and holiday lets

Regulation 6 of the Renting Homes (Fitness for Human Habitation) (Wales) Regulations 2022 requires a valid electrical condition report for the dwelling. A report is valid for five years, or less if it sets an earlier date for the next inspection. The contract-holder must get a copy within 14 days. Regulation 6 (opens in a new tab).

The regulations are made under section 94 of the Renting Homes (Wales) Act 2016. Introductory text (opens in a new tab). Section 94 provides for regulations on fitness for the purposes of section 91(1). Section 94 (opens in a new tab). Section 91 places the fitness duty on the landlord under a secure contract or a standard contract. Section 91 (opens in a new tab). Schedule 2 says a tenancy or licence that gives the right to occupy a dwelling for the purposes of a holiday is not an occupation contract, unless the landlord gives notice that it is to be one. Schedule 2, paragraph 3 (opens in a new tab).

No electrical inspection rule for holiday lets is in force in Wales in the sources this site read. Wales has a newer law that is not in force yet. The Development of Tourism and Regulation of Visitor Accommodation (Wales) Act 2026 will require premises offering regulated visitor accommodation to be licensed. Its electrical maintenance standard needs a valid electrical condition report from a qualified person, valid for up to 5 years, and a written record of any remedial work it calls for. Most of the Act starts on a day Welsh Ministers set, or on 4 March 2030 if no earlier day is set, and Ministers can move that date by up to two years. Section 10 of the 2026 Act (opens in a new tab) and section 61 (opens in a new tab).

Welsh guidance on electrical safety for visitor accommodation: Not checked yet.

Northern Ireland

Not checked yet

This site has not read an official page on electrical safety for holiday lets in Northern Ireland. Nothing is stated here until that is done.

Holiday let electrical rules side by side

NationFixed wiring (EICR)Portable appliances (PAT)
Englandgov.uk points to HSE and the rented-sector guidance. The five-year rule covers an only or main residenceHSE workplace guidance: maintain to prevent danger. The law does not require an annual test
WalesFive-year report rule sits in the Renting Homes rules. A holiday tenancy or licence is not an occupation contract without notice. A 2026 Act, not yet in force, sets a 5-year report for licensed visitor accommodationNot checked yet
ScotlandLicence condition. Inspection at least every five years and an EICRLicence condition. PAT report and dated, signed labels. Interval not stated
Northern IrelandNot checked yetNot checked yet

How to read this page

Sources

Found something wrong or out of date? Report it and it will be checked.

Check which rules apply with the checker or see the rules nation by nation.