Smoke and carbon monoxide alarms in holiday lets

Alarm rules for a holiday let come from a different source in each UK nation. The rented home alarm rules in England and Wales are written for tenancies and occupation contracts, so this page keeps them apart from the holiday let guidance.

At a glance

  1. England and Wales: the official guides for small paying guest accommodation say smoke alarms should be in hallways, stairs, living rooms and bedrooms, with heat alarms in kitchens, all interlinked.
  2. Both guides say a carbon monoxide alarm should be provided where a room has a fuel-burning appliance.
  3. Both guides say alarms in self-catering lets should be tested at each change of guests.
  4. Scotland: a licence condition says you must have satisfactory equipment to detect and warn of fire and carbon monoxide.
  5. The England alarm regulations apply to tenancies of an only or main residence. Their definitions and list of excluded tenancies do not mention holiday lets.

Official pages read 22 November 2026. This is general information. It is not legal advice.

Holiday let alarm rules by nation

NationSmoke and heat alarmsCarbon monoxide alarms
EnglandGuide: interlinked smoke alarms in hallways, corridors, staircases, lounges, dining rooms and bedrooms. Heat alarms in every kitchen.Guide: detectors should be provided where living accommodation has a gas or solid fuel-burning appliance.
WalesGuide: the same locations, interlinked.Guide: an alarm should be in each room with an appliance that runs on gas, oil or solid fuel.
ScotlandLicence condition: satisfactory equipment to detect and warn of fire. Detail in the tolerable standard guidance.Licence condition: satisfactory equipment to detect and warn of carbon monoxide.
Northern IrelandNot checked yetNot checked yet

Sources: England guide (opens in a new tab), Wales guide (opens in a new tab) and Scottish guidance for hosts (opens in a new tab). The England and Wales rows are guidance, so they say "should". The Scotland rows are licence conditions, so they say "must".

England: what the paying guest fire guide says

The Home Office guide (opens in a new tab) covers small paying guest accommodation in England. gov.uk's holiday let rules page (opens in a new tab) says you must follow it for up to 10 people or 2 floors. On alarms the guide says:

  1. Smoke alarms should be installed in hallways, corridors, staircases, lounges, dining rooms and bedrooms.
  2. Heat alarms should be installed in every kitchen and in rooms such as laundry or utility rooms where smoke alarms might give false alarms.
  3. Roof voids that contain combustible materials should also have detection. Smoke or heat alarms are not normally needed in bathrooms or toilets.
  4. All smoke and heat alarms should be interlinked, by wiring or radio, so they all sound together.
  5. They should be mains powered with a tamper-proof battery backup, known as Grade D1. Long-life sealed battery alarms, known as Grade F1, may be acceptable as a short-term measure of around 2 to 3 years.
  6. Carbon monoxide detectors should be provided where living accommodation contains a gas or solid fuel-burning appliance.

The guide says domestic alarms should be tested monthly. In self-catering lets with no staff or owner present, the tests should be done at each change of occupancy. It says smoke alarms typically last around 10 years. It also mentions vibrating pads and flashing beacons for guests who are Deaf or hard of hearing.

England: the alarm regulations for tenancies

The Smoke and Carbon Monoxide Alarm (England) Regulations 2015 were amended from 1 October 2022. They place duties on the landlord of a specified tenancy. Regulation 2 (opens in a new tab) defines that as a tenancy of residential premises in England that gives a right to occupy as an only or main residence and provides for rent.

TopicWhat the regulations say
WhoThe relevant landlord of a specified tenancy. A Schedule (opens in a new tab) lists excluded tenancies, such as shared accommodation with the landlord and student halls.
Smoke alarmsOne on each storey with a room used wholly or partly as living accommodation.
Carbon monoxide alarmsIn any room used as living accommodation that contains a fixed combustion appliance other than a gas cooker.
ChecksEach alarm must be in proper working order on the day a new tenancy begins.
RepairsA faulty alarm reported on or after 1 October 2022 must be repaired or replaced as soon as reasonably practicable.
PenaltyThe gov.uk booklet says the council can impose a fine of up to £5,000 where a landlord fails to comply with a remedial notice.

Sources: regulation 4 as amended (opens in a new tab) and the gov.uk Q&A booklet (opens in a new tab), last updated 29 July 2022.

Neither regulation 2 nor the Schedule mentions holiday lets, and the booklet does not either. The gov.uk holiday let page lists the booklet under guidance it says you must follow. This site has not found an official page that says how the tenancy regulations apply to holiday guests. The paying guest guide above is the source written for holiday lets.

Wales: guest accommodation guide and tenancy rules

The Welsh Government guide (opens in a new tab) gives the same smoke and heat alarm locations as England. It says all alarms should be interlinked, preferably mains powered with a battery backup (Grade D1). It says Grade F1 sealed battery alarms may be acceptable for around 2 to 3 years. It says to provide a carbon monoxide alarm in each room with an appliance that runs on gas, oil or solid fuel. In self-catering lets with no staff or owner present, the weekly and monthly tests should be done at each change of occupancy.

Wales also has alarm rules for rented homes. Regulation 5 of the fitness for human habitation regulations (opens in a new tab) says the landlord must make sure there is a mains-connected, interlinked smoke alarm on each storey. It requires a carbon monoxide alarm in each room with a gas, oil-fired or solid fuel appliance. Those regulations use the terms of the Renting Homes (Wales) Act 2016. Schedule 2 of the Act (opens in a new tab) says a tenancy or licence for the purposes of a holiday is not an occupation contract unless the landlord gives notice that it is.

Wales has a newer law that is not in force yet. The Development of Tourism and Regulation of Visitor Accommodation (Wales) Act 2026 will require premises offering regulated visitor accommodation to be licensed. Its carbon monoxide standard needs a working carbon monoxide alarm in any room with a gas, oil-fired or solid fuel appliance. Most of the Act starts on a day Welsh Ministers set, or on 4 March 2030 if no earlier day is set, and Ministers can move that date by up to two years. Section 12 of the 2026 Act (opens in a new tab) and section 61 (opens in a new tab).

Scotland: licence conditions on alarms

Scottish Government guidance for hosts (opens in a new tab) says you must have satisfactory equipment to detect and warn of fire and carbon monoxide. It says you must fit and maintain working smoke and carbon monoxide alarms. mygov.scot (opens in a new tab) says the accommodation must have adequate heat, smoke and carbon monoxide alarms. Guests must be able to find instructions on what to do if the carbon monoxide alarm sounds.

The guidance for hosts points to the tolerable standard guidance for the detail:

AlarmWhat the tolerable standard guidance says
Smoke alarmsOne in the room most used for daytime living, usually the living room. One in every circulation space on each storey, such as hallways and landings.
Heat alarmOne in every kitchen.
Linking and powerThe required alarms must be interlinked and ceiling mounted. Mains wired with battery backup, or tamper-proof long-life lithium battery alarms.
Carbon monoxideIn every room with a fixed combustion appliance or a flue. An appliance used solely for cooking does not need one. Battery alarms should last the working life of the detector. They do not need to be interlinked.

Sources: chapter 16 on fire detection (opens in a new tab) and chapter 17 on carbon monoxide (opens in a new tab), published 20 June 2023.

The guidance for hosts also refers to Annex 2 of the practical fire safety guidance (opens in a new tab). For small self-catering premises it says:

Source: Annex 2 (opens in a new tab) paragraphs 10 to 14.

The Scotland licensing page covers the other licence conditions.

Northern Ireland

Not checked yet

No official page for Northern Ireland has been read for this guide. Nothing is stated here until that is done.

Sources

Found something wrong or out of date? Report it and it will be checked.